Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Full dent. sci ; 1(3): 242-247, abr.-jun. 2010. ilus
Article in Portuguese | LILACS, BBO | ID: lil-642946

ABSTRACT

Um dos erros mais frequentes em reabilitação oral é a montagem incorreta dos modelos de gesso no articulador. Os modelos de estudo e, principalmente, os modelos de trabalho, devem ser rigorosamente posicionados numa relação funcional no articulador, que irá representar a maxila e a mandíbula com a articulação temporomandibular e os movimentos mandibulares. O objetivo deste trabalho foi avaliar através de um estudo laboratorial a precisão do articulador A7 Fix Bio-Art padronizado, quando simuladores dos modelos são transferidos de um articulador para outro. Para a realização desta pesquisa foram selecionados dez articuladores e desses, um foi designado como articulador mestre. Foram confeccionadas peças que representassem as duas arcadas e essas foram montadas no articulador mestre e transferidos para os outros nove articuladores e avaliado na transferência os seguintes critérios: efetividade do contato com o carbono (avaliação vertical), coincidência dos parafusos com os orifícios (avaliação horizontal), e coincidência do pino incisal com a linha cheia (avaliação vertical). Os resultados encontrados foram de que em todas as transferências os três parafusos do modelo superior coincidiram com as concavidades realizadas no modelo inferior; a relação de contato interoclusal permaneceu em todas as transferências; somente em dois articuladores houve 1 mm de discrepância em relação a linha cheia. Conclui-se que o articulador A7 Fix (Bio-Art) padronizado permitiu o intercâmbio dos modelos de gesso entre os articuladores.


One of the most usual mistakes in oral rehabilitation is the incorrect assemblage of the cast models on the articulating device. The study models and mainly the work models must be strictly placed to a functional relation on the articulator, which will represent the maxilla and the mandible, with the temporomandibular articulation and the mandible movements. This work aims at evaluating, through a laboratorial experimental study, the accuracy of the 7 Fix Bio-Art standardized when the simulators of the models are transferred from one articulator to another. Ten articulators were selected for this study and one of them was chosen as the master articulator. Parts representing the two articulators were manufactured and assembled on the master articulator and transferred to other nine articulators and in the transference the following criterion were evaluated: effectiveness of the contact with the carbon (vertical evaluation), coincidence of the screws with the holes (horizontal evaluation), and coincidence of the incisal pin with the full line (vertical evaluation) the results found at the end of the test were: in all transference of the three screws of the superior model fit the concavities in the inferior model; the relation of the interoclusal contact happened in the proper way in all transference; only in two of the articulators there was a difference of 1 mm in relation to the full line. It was concluded that the standardization of the A7 FIX (Bio-Art) allowed the interchange of the models among the articulators’ devices.


Subject(s)
Dental Articulators , Esthetics, Dental , Jaw Relation Record , Mouth Rehabilitation , Dental Prosthesis/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL